Mitsubishi Electric MELSEC iQ-R Series User Manual page 467

Master/local module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

List of buffer memory addresses (EtherNet/IP)
The following table lists the buffer memory addresses related to EtherNet/IP.
Address
Address
(decimal)
(hexadecimal)
7340032
700000H
7340033
700001H
7340034 to 7340047
700002H to 70000FH
7340048
700010H
7340049
700011H
7340050 to 7340051
700012H to 700013H
7340052
700014H
7340053
700015H
7340054
700016H
7340055 to 7340064
700017H to 700020H
7340065 to 7340084
700021H to 700034H
7340085 to 7340087
700035H to 700037H
7340088 to 7340095
700038H to 70003FH
7340096
700040H
7340097
700041H
7340098 to 7340103
700042H to 700047H
7340104
700048H
7340105
700049H
7340106 to 7348223
70004AH to 701FFFH
7348224 to 7533055
702000H to 72F1FFH
7533056 to 7536639
72F200H to 72FFFFH
7536640 to 7721471
730000H to 75D1FFH
7721472 to 7729151
75D200H to 75EFFFH
7729152 to 7729407
75F000H to 75F0FFH
7729408 to 7729663
75F100H to 75F1FFH
7729664 to 7730175
75F200H to 75F3FFH
7730176 to 7730687
75F400H to 75F5FFH
7730688 to 7734271
75F600H to 7603FFH
7734272 to 7734287
760400H to 76040FH
7734288 to 7734303
760410H to 76041FH
7734304 to 7734319
760420H to 76042FH
7734320 to 7734527
760430H to 7604FFH
7734528 to 7735039
760500H to 7606FFH
7735040 to 7735551
760700H to 7608FFH
7735552 to 7735807
760900H to 7609FFH
7735808 to 7735823
760A00H to 760A0FH
7735824 to 7735839
760A10H to 760A1FH
7735840 to 7737343
760A20H to 760FFFH
7737344 to 7737363
761000H to 7623FFH
7742464 to 7749631
762400H to 763FFFH
Name
System area
Intelligent auto refresh status
System area
PING test request area
PING test response area
System area
Ethernet address (MAC address)
System area
EtherNet/IP communication start request
EtherNet/IP communication in-process status
System area
EtherNet/IP communication continuation specification request
EtherNet/IP communication continuation specification status
System area
Class1 Input Area
System area
Class1 Output Area
System area
Class1 Input data length
Class1 Output data length
Class1 start offset address to the
input/output data
System area
Class1 communication status
System area
Class1 connection error status
System area
Class1 cyclic pause specification
Class1 cyclic pause status
System area
Connection information area
System area
Communication time check
Transmission count
IP Address
Total number of packet
transmissions
Receive count
Loss count
Error code
Class1 start offset address to the
input data
Class1 start offset address to the
output data
Class1 data link status
Class1 error status
Class1 reserved station
Input
Output
Appendix 3 Buffer Memory
Initial value
Read, write
Module
Read
parameter
setting value
0
Read, write
0
Read, write
0
Read, write
0
Read
0
Read
0
Read
0
Read
Module-
Read
specific
0
Read, write
0
Read
0
Read, write
0
Read
0
Read
0
Read, write
0
Read
0
Read
FFFFH
Read
FFFFH
Read
0
Read
0
Read
0
Read
0
Read
0
Read
0
Read, write
0
Read
0
Read
APPX
465
A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec iq-r cc-link ie tsn plus

Table of Contents