EtherNet/IP communication control
■EtherNet/IP communication start request (Un\G7340096)
Set a value other than 0 to make a request to start the EtherNet/IP communications.
• Other than 0: EtherNet/IP communication start request
• 0: EtherNet/IP communication stop request
To start EtherNet/IP communications by setting a value other than 0 for 'EtherNet/IP communication start
request (Un\G7340096)', set all 'Class1 cyclic pause specification' (Un\G7735808 to Un\G7735823) to 0.
When 'Class1 cyclic pause specification' (Un\G7735808 to Un\G7735823) is not all set to 0, EtherNet/IP
communications will not start even if a value other than 0 is set for 'EtherNet/IP communication start request'
(Un\G7340096).
In this case, 2 (cannot start) is stored for 'EtherNet/IP communication start status' (Un\G7340097).
The following figure shows the timing chart for 'EtherNet/IP communication start request' (Un\G7340096).
• EtherNet/IP communication has started (normal)
Performed by a program
Performed by the RJ71GN11-EIP
'EtherNet/IP communication start
request' (Un\G7340096)
'EtherNet/IP communication in process'
(X10)
Starting and stopping of EtherNet/IP
communications
'Class1 start offset address to the input/output data'
(Un\G7729664 to Un\G7730687)
'Class3/UCMM start offset address to the data
(tag communications)'
(Un\G8463616 to Un\G8464127)
'Class1 reserved station'
(Un\G7734304 to Un\G7734319)
'Class3 reserved station'
(Un\G8464416 to Un\G8464431)
'Class1 data link status'
(Un\G7734272 to Un\G7734287)
'Class1 Input Area'
(Un\G7348224 to Un\G7533055)
'Class3/UCMM data area (tag communications)'
(Un\G8278016 to Un\G8462847)
'Class1 Output Area'
(Un\G7536640 to Un\G7721471)
'Class3/UCMM data area (tag communications)'
(Un\G8278016 to Un\G8462847)
(1) A value other than 0 set for EtherNet/IP communication start request
(2) 0 set for EtherNet/IP communication start request
(3) EtherNet/IP communication started
(4) EtherNet/IP communication stopped
(5) Start offset address
(6) Reserved status
(7) Communication status
(8) Input data
(9) Output data
*1 If the own station is a scanner, the last value may not be retained if the cable is disconnected or the external device is removed. If the
own station is an adapter, the last value will be retained.
APPX
488
Appendix 3 Buffer Memory
Parameter setting
(1)
(1)
Communicating (EtherNet/IP)
(2)
(2)
Normal startup
Normal startup
(3)
(5)
(6)
(7)
(8)
(9)
(4)
0
0
*1
0