Mitsubishi Electric MELSEC iQ-R Series User Manual page 531

Master/local module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Name of variable
Description
Sn  (RXb + RWrb) + Ln  (LBxmb + LWxmb) + Sn
n4
RXb: Value of (Total number of points of "RX setting" of main modules)/(11744  Sn) rounded up to the nearest integer
RWrb: Value of (Total number of points of "RWr setting" of main modules)/(734  Sn) rounded up to the nearest integer
LBxmb: Value of (Total number of points of "LB setting" excluding master station)/(11744  Ln) rounded up to the nearest
integer
LWxmb: Value of (Total number of points of "LW setting" excluding master station)/(734  Ln) rounded up to the nearest
integer
((Total number of points of "RX setting" of main modules)/8) + ((Total number of points of "RWr setting" of main modules)  2)
nds
+ ((Total number of points of "LB setting" excluding the master station)/8) + ((Total number of points of "LW setting" excluding
the master station)  2) + 8  Sn
(ndl + 20  n6)/1488
n5
n6
(ndl-8)/1468 + 1
(RXl/8) + (RWrl  2) + (LBl/8) + (LWl  2) + 8
ndl
RXl: Number of points of "RX setting" of main modules of the slave station
RWrl: Number of points of "RWr setting" of main modules of the slave station
points
LBl: Number of points of "LB setting" of the slave station
LWl: Number of points of "LW setting" of the slave station
n7
When "CC-Link IE TSN Class Setting" is set to "Mixture of CC-Link IE TSN Class B/A or CC-Link IE TSN Class A Only" and
"TSN HUB Setting" is set to "Not to Use TSN HUB": 4
Other than the above: 0
en1
120
i = 1
en1
However, when endm
When mf
mf
i
However, the value is 0 when the calculation result of mf
en2
120
i = 1
en2
However, when endm
endm
120
i = 1
endm
en3
120
i = 1
en3
However, when ends
When sf
sf
= 1488-mod
i
However, the value is 0 when the calculation result of sf
en1
i
*3
 16)/1488)
= ((endm
+ en2
-k
i
i
i
i
is 0, en1
is 0.
i
i
16, k
>16, k
= 1, and when mf
i
i
i
= 1488-mod
mod: Remainder of {((mRy
+ (mRy
/1472)
i
i
i: Station number
mRy
: Number of points of "RY setting" of main modules with station No.i/8
i
: Number of points of "RWw setting" of main modules with station No.i  2
mRWw
i
en2
i
= eRyn
+ eRWwn
+ ((endm
+ (eRyn
i
i
i
i
is 0, en2
is 0.
i
i
i: Station number
eRyn
: 0 (fixed)
i
eRWwn
: Total number of extension modules with station No.i whose number of points of "RWw setting" is more than 0
i
endm
i
 2
= eRyAll
/8 + eRWwAll
i
i
i
i: Station number
eRyAll
: 0 (fixed)
i
eRWwAll
: Total number of points of "RWw setting" of extension modules with station No.i
i
en3
i
*3
 20)/1488)
= ((ends
+ en4
-k
i
i
i
i
is 0, en3
is 0.
i
i
20, k
>20, k
= 1, and when sf
i
i
i
i
mod: Remainder of {((mRx
+ (mRx
/1468)
i
i
i: Station number
mRx
: Number of points of "RX setting" of main modules with station No.i/8
i
: Number of points of "RWr setting" of main modules with station No.i  2
mRWr
i
*2
to be used as the maximum number of link points
*2
to be used as the maximum number of link points
*2
to be used as the maximum number of link points
= 0.
i
*3
 16) + (mRWw
+ (mRWw
/1472)
i
i
is 1488.
i
*3
)  16)/1488)
+ eRWwn
-1
i
i
= 0.
*3
 20) + (mRWr
+ (mRWr
/1468)
i
i
is 1488.
i
Appendix 6 CC-Link IE TSN Processing Time
*2
to be used as the maximum number of link
*3
 16))/1488}
*3
 20))/1488}
APPX
A
529