44- 2
Extra equipment – 9500
Dry powder extinguisher
T-code
403-414, 669-671, 716-718
Date
2005-06-01
44.1.1 Regular checks of the powder
extinguisher – truck driver
The following points can be found on the powder extinguisher and
these can also be found in the driver's manual for the truck.
• Check regularly that the pressure gauge indicator is in the green
field. If the indicator is in the red field, the apparatus is useless and
must be recharged.
• Recharge the extinguisher immediately after use. Contact an au-
thorised service company.
• Make sure that the extinguisher is checked once a year by a quali-
fied service engineer (from an authorised service company for fire
protection) and that a workshop review is carried out every 10 years.
Only material/parts approved by the manufacturer may be used.
44.1.2 Inspection of powder extinguisher in
service inspection of the truck
The powder extinguisher must be checked once a year in connection
with servicing of the truck.
• Check that the pressure gauge indicator is in the green field. If the in-
dicator is in the red field, the apparatus is useless and must be re-
charged.
• Check that the powder extinguisher is intact and in working order
and is in the correct location in the truck.
• If the extinguisher does not appear to function satisfactorily, make
sure that an authorised service company is contacted.