BT REFLEX RR B Service Manual page 284

Table of Contents

Advertisement

24- 72
Electronic card – 5710
Error Codes
T-code
403-414, 669-671, 716-718
Date
2005-06-01
Code
111
Description
Potentiometer R2 for brake pedal gives incorrect
voltage (<0.4 or >4.6 V)
Error mode
Critical error
Error cause
1. Faulty potentiometer/wiring
2. Defective electronic card A5
Comments
Potentiometer R2, brake
1. Check that R2 is located in its bracket.
- Check that the voltage across R2 (1 and 2) is 7-7.5 VDC.
- Check that there is no play or oxidisation on the connector pins
on terminal X36.
- The voltage on input 502 should be 1.7 VDC when R2 is in the
neutral position and 4.1 VDC with the brake pedal is fully actuat-
ed.
- If the voltage is < 0.4 VDC the 7-7.5 V voltage is missing, if the
voltage is > 46 VDC, 0 V is missing. If the cables are intact, re-
place potentiometer R2.
2. If the correct voltage is on input 505 and the fault remains, re-
Service Manual