24- 16
Electronic card – 5710
Parameter setting of all parameters
T-code
403-414, 669-671, 716-718
Date
2005-06-01
24.5.10 Parameters 15 and 16
When these parameters are set to a value >0, monitoring of the poten-
tiometers and valves for the two optional hydraulic functions is activat-
ed. The magnitude of the value determines the pressure applied for
these functions.
24.5.11 Parameters 17 and 18
If the truck is equipped with height measurement, these two parame-
ters can be used to set the maximum lift heights. The second maximum
height value must be equal to or larger than the first maximum height
value. The maximum lift height is set using parameter 29.
If the truck is not equipped with height measurement U10, set this
parameter to 0.
The parameter should be set to 0 if the truck is not equipped with height
measurement, otherwise when using the switch for maximum lift height
S32, the bypass of height measurement does not work.