24- 38
Electronic card – 5710
Warning Codes without registration
T-code
403-414, 669-671, 716-718
Date
2005-06-01
Code
25
Description
Output stage error
Error mode
General error
Error cause
1. Emergency switch S133 for Y12
(retracted mast) activated
2. See codes 50-62 for more information
Comments
1. Check S133, which is located under the arm panel.
2. To view the registers with recorded warning codes, see the
section "Display and programming":
The number of the address register is displayed on the left side, while
the value is displayed on the right side.
Code
26
Description
Input stage error
Error mode
General error
Error cause
1. See codes 90-94 for more information
Comments
1. Proceed as follows when you wish to look in the register for
warning codes when registering, see the section "Display and
programming".
The number of the address register is displayed on the left side, while
the value is displayed on the right side.