24- 96
Electronic card – 5710
Error Codes
T-code
403-414, 669-671, 716-718
Date
2005-06-01
Code
229 - 230
Description
Too high voltage on lift regulator
Error mode
Lift regulator error
Error cause
1. Defective battery
2. Poor contact at K10's contactor points
3. Defective lift regulator, A2
Comments
Battery circuit
1. Check that the battery is okay, sufficiently charged and of the
right model.
2. Check the contactor points on K10.
3. If everything is okay, replace A2.
Service Manual
REFLEX RR B/E, RR B/E CC
https://www.forkliftpdfmanuals.com/
Valid from serial number
713962-
Order number
218920-040