Error Codes
Valid from serial number
713962-
Order number
218920-040
Code
107
Description
The main contactor K10 does not close during truck
start-up and the emergency stop switch does not
operate
Error mode
Critical error
Error cause
1. Defective contactor K10
2. Defective electronic card A5
Comments
Main contactor, K10, contactor points
1. Check the voltage on terminal 808. It must be nominal battery
plus, i.e. + 48 VDC, when the truck is stated.
- If there is no voltage, check fuse F62 (10 A).
- If the fuse has not blown, check that cable 23 is intact.
- If cable 23 is okay, check the contactor points on K10.
- If the contactor points are okay, check that cable 1 is okay.
2. If there is a voltage of +48 VDC on the card's terminal 808 and
the fault remains, replace the A5 card.
Service Manual
https://www.forkliftpdfmanuals.com/
REFLEX RR B/E, RR B/E CC
T-code
403-414, 669-671, 716-718
Date
2005-06-01
24- 69