BT REFLEX RR B Service Manual page 248

Table of Contents

Advertisement

24- 36
Electronic card – 5710
Warning Codes without registration
T-code
403-414, 669-671, 716-718
Date
2005-06-01
Code
23
Description
Potentiometer R12 for the mast reach in/out gives
incorrect voltage when ignition is switched on (+/-0.6
V).
Error mode
Start up error
Error cause
1. Activated joystick at start up
2. Faulty potentiometer/wiring
3. Calibration error
4. Defective electronic card A5
Comments
Mast reach/retraction control, joystick R12
1. Check that the joystick for the mast's reach/retraction opera-
tions has not stuck in an actuated position.
2. Check that R12 is located in its bracket.
Check that there is no play or oxidisation on the connector
pins on terminal X11. The voltage on input 504 should be 3,7 +/
-0,6 VDC when R12 is correctly adjusted.
3. Calibration of the mast's reach/retraction control.
- Check that the joystick is not actuated and is in its neutral posi-
tion.
- Restart the truck.
Service Manual
REFLEX RR B/E, RR B/E CC
https://www.forkliftpdfmanuals.com/
Valid from serial number
713962-
Order number
218920-040
© BT Europe AB