Electrical system – 5000
Functional description
Valid from serial number
713962-
Order number
218920-040
21.4.17 Height indication
Measuring starts in the main lifting zone when the reference switch S45
is activated and sends a signal to A5. Pulse sensor U10 sends pulses
to A5, which starts by displaying the programmed free lift height on the
display A8.
Designation
HEIGHT COUNTER
HEIGHT COUNTER
HEIGHT REFERENCE
21.4.18 Height pre-set
Measuring starts in the main lifting zone when the reference switch S45
is activated and sends a signal to A5. Pulse sensor U10 sends pulses
to A5, which starts by displaying the programmed free lift height on the
displays A7 and A8. The forks stop at the first pre-programmed height
when A5, via pulse generator U10, reaches the correct height. The halt
is initiated by A5 regulating the pump motor speed using A2 and valves
for fork lifting and lowering. The driver picks up or deposits the load
manually. When the driver again presses the hydraulic control for lift-
ing/lowering, the forks continue to the next pre-programmed level. See
C code 9000.
Designation
HEIGHT COUNTER
HEIGHT COUNTER
HEIGHT REFERENCE
21.4.19 Weighing
• Collect load on forks.
• Lift the fork off the floor and the weight will be shown on the display.
The load's weight will be shown in the display window at intervals of 50
kg, with a tolerance of ± 25 kg. Display automatically reverts to time
measurement after 10 seconds. For calibration, see C code 5710.
Service Manual
https://www.forkliftpdfmanuals.com/
Diode number
301
302
303
Diode number
301
302
303
REFLEX RR B,E RR B,E CC
T-code
403-414, 669-671, 716-718
Date
2005-06-01
21- 45