24- 70
Electronic card – 5710
Error Codes
T-code
403-414, 669-671, 716-718
Date
2005-06-01
Code
108
Description
The main contactor does not open when the red
pushbutton on the keypad is depressed and the
emergency stop switch does not operate
Error mode
Critical error
Error cause
1. Defective contactor K10
2. Defective electronic card A5
Comments
Main contactor, K10, contactor points
1. Check the voltage on terminal 808. It must be 0 VDC when the
red pushbutton on the keypad is depressed.
- If there is voltage, check whether the contactor points on K10 are
welded together.
- If the contactor points are okay, check that cable 23 is not short-
circuited to any live parts.
2. If the voltage is 0 VDC on the card's terminal 808 and the fault
remains, replace the A5 card.