Electronic card – 5710
Error Codes
T-code
403-414, 669-671, 716-718
Date
2005-06-01
Code
Description
Error mode
Error cause
Comments
CAN – communication between A5 and A1
TRANSISTOR PANEL, DRIVE
A1
F1
125A/160A
B+
B-
7
4
3
5
6
1
1. Check that the cables 117, 118, 119 and 120 are not short-
circuited or are broken. Also check the resistor R101.
2. Try using a new drive regulator A1.
Service Manual
https://www.forkliftpdfmanuals.com/
Valid from serial number
713962-
Order number
218920-040
151
No communication with the drive regulator on start-
up
Drive regulator error
1. Faulty CAN wiring/resistance
2. Defekt körregulator
2
U
3
V
4
W
12
13
10
11
120 OHM / 0.6W
R100
REFLEX RR B/E, RR B/E CC
ELECTRONIC CARD
A5
117
401
OUT CAN +15VDC
118
402
OUT CAN GND
119
403
OUT/IN CAN H
120
404
OUT/IN CAN L
© BT Europe AB