B+
15 Nm
U
© BT Europe AB
Transistor panel – 5460
Frequency converter
Valid from serial number
713962-
Order number
218920-040
23- Transistor panel – 5460
23.1 Frequency converter
23.1 General description
The frequency converter is equipped with a green LED that indicates
OK status.
On start-up, it flashes twice and then remains on.
Basic software to control the motor is stored in the frequency converter.
The frequency converter has internal monitoring of CAN communica-
tions DC voltage levels, intrinsic temperature and motor temperature.
Any detected function errors are registered by the frequency converter
and the information sent via CAN to the main card A5, which registers
the error code and presents the corresponding code on the instrument
panel display.
The frequency converter can be reprogrammed via CAN.
K1
V
W
B-
Service Manual
https://www.forkliftpdfmanuals.com/
1
2
8
9
REFLEX RR B/E, RR B/E CC
T-code
403-414, 669-671, 716-718
Date
2005-06-01
3
4
5
6
7
10
11 12 13
23- 1

Hide quick links: