BT REFLEX RR B Service Manual page 295

Table of Contents

Advertisement

© BT Europe AB
Electronic card – 5710
Error Codes
Valid from serial number
713962-
Order number
218920-040
Code
Description
Error mode
Error cause
Comments
CAN communication
TRANSISTOR PANEL, DRIVE
A1
F1
125A/160A
8
B+
2
U
40
B-
3
V
14
7
4
W
11
4
10
3
12
12
5
13
13
6
10
22
1
11
SERVICE KEY INTERFACE
X41
117
X45
X31
1
118
X45
X31
2
X31
119
X45
3
120
X45
X31
4
120 OHM / 0.6W
R100
1. Check that the cables 117, 118, 119 and 120 are not short-
circuited or are broken. Also check the resistors R100 and
R101.
2. Check that output 401 on the A5 card has +15 VDC.
3. Try using a new drive regulator A1.
4. Try using a new lift regulator A2.
5. Try using a new A5 card.
Service Manual
https://www.forkliftpdfmanuals.com/
150
No communication with the motor regulators on start-
up
Drive regulator error and lift regulator error
1. Faulty CAN wiring/resistance
2. 15 no V
3. Defective drive regulator A1
4. Defective lift regulator A2
5. Defective electronic card A5
ELECTRONIC CARD
A5
117
401
OUT CAN +15VDC
118
402
OUT CAN GND
119
403
OUT/IN CAN H
120
404
OUT/IN CAN L
REFLEX RR B/E, RR B/E CC
T-code
403-414, 669-671, 716-718
Date
2005-06-01
TRANSISTOR PANEL, PUMP
A2
F3
200A/250A/300A
8
B+
40
B-
16
8 ID
19
7
16
4
15
3
17
5
18
6
22
1
117
118
119
120
5
U
6
V
7
W
117
12
118
13
119
10
120
11
120 OHM / 0.6W
R101
24- 83

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents