© BT Europe AB
Keypad
Function
Valid from serial number
713962-
Order number
218920-040
25.3 Function
Five different log-in functions can be set for the keypad. Through con-
nection X3:5 and X3:9 the system negative is connected in different
ways.
After changing the function you should leave the keypad dead during
approx. 1 minute for the new function to start working.
The zeros that exists in the beginning of the driver PIN-code does not
need to be designated.
25.3.1 Function 0
• Connection 1 and 2 (X3:5, X3:9) not connected to the system nega-
tive.
• Driver PIN-code in keypad is used.
• Log-in with 1-4 digits and green pushbutton. Not 1.
• Driver profiles i A5 card are used.
• Log-out with red pushbutton.
25.3.2 Function 1
• Connection 1 (X3:5) connected to system negative.
• Parameter 39 must be set to 1 or 2 (key). See chapter "Displaying
and programming".
• Driver PIN-codes in keypad is used.
• Log-in with 1-4 digits and green pushbutton.
• Driver profiles i A5 card are used.
• Log-out with red pushbutton.
25.3.3 Function 2
• Connection 2 (X3:9) connected to system negative.
• Driver PIN-codes in keypad are not used without verification in the
TLS. The TLS sends back that the driver is approved. Not. 1.
• Log-in with 1-5 digits and green pushbutton.
• Driver profiles i A5 card are used.
• Log-out with red pushbutton.
Service Manual
https://www.forkliftpdfmanuals.com/
REFLEX RR B/E, RR B/E CC
T-code
403-414, 669-671, 716-718
Date
2005-06-01
25- 101