BT REFLEX RR B Service Manual page 244

Table of Contents

Advertisement

24- 32
Electronic card – 5710
Warning Codes without registration
T-code
403-414, 669-671, 716-718
Date
2005-06-01
Code
17
Description
Voltage from the brake pedal potentiometer R2 is
outside of the calibrated value at start up
(+/-0.2 V).
Error mode
Start up error
Error cause
1. Activated brake pedal at start up
2. Faulty potentiometer/bracket/wiring
3. Calibration error.
4. Defective electronic card A5
Comments
Manoeuvre to neutral position
Brakes, R2
1. Check that the brake pedal has not stuck in the actuated posi-
tion.
2. Check that R2 is located in its bracket.
Check that there is no play or oxidisation on the connector
pins on terminal X36. The voltage on input 502 should be 1.7 +/
- 0.2 VDC when R2 is correctly mechanically adjusted.
3. For calibration of the brake control, see the section "Parame-
ter setting" in this manual.
(Deactuated position).
4. If the voltage on input 502 is correct and calibration does not
rectify the problem, then replace the A5 electronic card.
Service Manual
REFLEX RR B/E, RR B/E CC
https://www.forkliftpdfmanuals.com/
Valid from serial number
713962-
Order number
218920-040