BT REFLEX RR B Service Manual page 429

Table of Contents

Advertisement

© BT Europe AB
Control/computer equipment – 8700
Function for truck report
Valid from serial number
713962-
Order number
218920-040
39.7 Function for truck report
It is possible to generate a report to a file or disk using the truck's con-
figuration and status. Select the <Tools | Generate truck report... menu
> or using the Truck report tool button. Save the report in the
Report.file.
Example of information generated in the truck report:
[GENERAL]
REPORT DATE-TIME=1999-12-09 07:42:14
CPC-PP SERIAL No=8002008
MACHINE NUMBER=392179
CUSTOMER=CUSTOMER 1
TECHNICIAN=NONAME
COMPANY=COMPANY 1
NOTES=Test report
[CAN NODES]
MAIN CARD=125
FORK CARD=-1
TRUCK TRACKER=-1
ACC LIFT CONTROLLER=0
ACC DRIVE CONTROLLER=0
CURTIS LIFT CONTROLLER=-1
[MAIN CARD CONFIGURATION]
SOFTWARE=169942-001
HARDWARE=169937-001
SERIAL NO=12112
[HOUR METERS]
A IGNITION TIME=1
B TOTAL MOVEMENT=0
C DRIVE MOTOR TIME=0
D PUMP MOTOR TIME=0
S SERVICE TIME=9
The content of certain rows can vary depending on the truck type.
Service Manual
https://www.forkliftpdfmanuals.com/
NAME
REFLEX RR B/E, RR B/E CC
T-code
403-414, 669-671, 716-718
Date
2005-06-01
[ERROR LOG]
01=55 99-12-09 06:11
02=55 99-12-08 20:54
03=55 99-12-08 14:26
04=231 99-12-08 14:16
05=55 99-12-08 14:11
.
.
.
50=55 99-12-08 14:40
[DRIVER PARAMETERS]
1=3
2=100
3=100
.
.
.
100=0
[TRUCK PARAMETERS]
11=100
12=80
13=10
39- 7