12- 8
Electric drive motor – 1760
Installation instructions for external temperature sensor
T-code
403-414, 669-671, 716-718
Date
2005-06-01
• Fasten the metallic lacquer and the sensor with masking tape and
allow it to harden.
• Remove the masking tape. The temperature sensor should now be
fixed in place and covered entirely by metallic lacquer.
• Remove the ferrite block from the old sensor and mount it on the ca-
ble to the new sensor.
• Remove the contact from the broken sensor, which is attached to
the motor.
• Place the new sensor contact in the old bracket and connect it to the
cabling.
• Fasten the old contact and its cabling using a cable tie so it cannot
damage anything.