24- 58
Electronic card – 5710
Warning codes with registration
T-code
403-414, 669-671, 716-718
Date
2005-06-01
Code
61
Description
Output 803 short circuit/breakage
Error mode
General error
Error cause
1. Emergency switch Y10/3 activated
2. Faulty wiring/valve Y10/3
3. Defective electronic card A5
Comments
Hydraulic valve Y10/3 engages fork lowering.
1. Check that the switch S132 is open.
2. Disconnect the cable 88 from output 803.
- Check that the connector pins make contact, no play and no oxi-
disation.
- Check that the cable 88 is intact between terminal 803 and the
terminals in X17 via X14.
- Measure the coil on Y10/3 between the white and black cables in
X17 with an ohmmeter. Resistance approx. 27 ohm.
- Check that cable 40 is intact from X17, via X14 to the battery neg-
ative.
3. If the fault remains, replace A5.
Service Manual
REFLEX RR B/E, RR B/E CC
https://www.forkliftpdfmanuals.com/
Valid from serial number
713962-
Order number
218920-040