24- 94
Electronic card – 5710
Error Codes
T-code
403-414, 669-671, 716-718
Date
2005-06-01
2. Check B2.
- Remove connection X12. Measure B2 in X12 with the ohmmeter,
approx. 570 ohm at 20
- Check that cable 16 is intact between X12 and terminal 4 on A1.
- Check that cable 19 is intact between X12 and terminal 7 on A1.
- Also check the connector pins on the terminals for play and oxidi-
sation.
Code
226 - 227
Description
Overheated lift regulator
Error mode
Lift regulator error
Error cause
1. Defective cooling fan
2. Defective motor cable/motor
3. Defective lift regulator
Comments
Restart possible
Pump motor circuits
1. Check the fan M12 by the regulators.
2. Check the motor cables 5, 6 and 7 and the pump motor M3.
3. If everything is okay, replace A2.
Service Manual
REFLEX RR B/E, RR B/E CC
https://www.forkliftpdfmanuals.com/
Valid from serial number
713962-
Order number
218920-040
o
C.
© BT Europe AB