41- 18
Positioning equipment – 9390
Error codes
T-code
403-414, 669-671, 716-718
Date
2005-06-01
41.13 Error codes
Error code
Remarks
Err 1
Requested height level not programmed or incor-
rect
Err 2
Forks have stopped outside the tolerance zone
(P5)
Err 9
Incorrect value entered when programming
Err flashing
Fault in communication between height pre-set
and truck computer
• Four lines appear at start-up. This shows that there has been no
communication between height pre-set and the main electronics.
The lines will disappear when communication is restored between
the units.
• Four dots appear on the display when the forks are in the free lift
zone.
• If the dots are flashing, this is an indication that the reference switch
was activated when the truck was started (e.g. the forks were above
the free lift zone). If the dots continue to flash after the forks have
been lowered, a fault may have occurred in the wiring or the height
reference switch.