24- 78
Electronic card – 5710
Error Codes
T-code
403-414, 669-671, 716-718
Date
2005-06-01
Code
127
Description
Communications error between steering processor
and master processor
Error mode
Steering error
Error cause
1. External interference (static electricity)
2. Defective electronic card A5
Comments
Restart can reset error
1. A temporary disturbance can have affected the card.
Try to restart the truck.
Code
128
Description
Memory cell for steering set point value contains
incorrect value
Error mode
Critical error
Error cause
1. External interference (static electricity)
2. Defective electronic card A5
Comments
Restart can reset error
1. A temporary disturbance can have affected the card.
Try to restart the truck.
Code
130
Description
Communications error between I/O processor and
master processor
Error mode
Critical error
Error cause
1. External interference (static electricity)
2. Defective electronic card A5
Comments
Restart can reset error
1. A temporary disturbance can have affected the card.
Try to restart the truck.