Positioning equipment – 9390
Function
Valid from serial number
713962-
Order number
218920-040
41.3 Function
Measuring starts in the main lifting zone when the reference switch
(S45) is activated and sends a signal to the electronic card (A5). The
pulse sensor (U10) sends pulses to A5, which starts by displaying the
programmed free lift height on the display (A8). The pulse sensor has
two channels, A and B, which relay signals with 90
This gives A5 information on whether the forks are moving up or down.
For connection, see Wiring Diagram, chapter 5000.
For programming the free lift height, see Setting Parameters, chapter
5710.
The steel wire should be wrapped one turn around the measuring
wheel and stretched taut so it does not slip.
U10
41.4 Display
The picture shows the rear side of the height indication display, and the
table explains the terminal numbers for contacts where I means input.
Service Manual
https://www.forkliftpdfmanuals.com/
S45
REFLEX RR B,E RR B,E CC
T-code
403-414, 669-671, 716-718
Date
2005-06-01
°
reciprocal ratio.
5 mm
A8
A5, A2
A7
41- 3