© BT Europe AB
Battery charger – 8340
Functional description
Valid from serial number
713962-
Order number
218920-040
Code
Error messages
E63
Error in EE-prom
E67
Battery acknowledgement error
E70
Data in the mother board's EE-prom is not valid
E72
Error in the mother board's EE-prom
E76
Error in EE-prom
E77
The content in the computer board's and the mother
board's EE-prom is not the same.
Reading statistics from the previous charge
The statistics remain in the system until a new charging process is
started or the battery is replaced. The statistics are stored in a register
with a three-digit number in the range 290–500. The most important are
shown in the following table.
• Press * register number *.
Register
Function (resolution, unit)
290
Voltage before start, 10 mV/cell.
291
Start current, % of the charger's rated current.
320
Final voltage, 10 mV/cell.
321
Final current, % of the charger's rated current.
340
Calculated withdrawn capacity, Ah
360
Total recharged capacity, non maintenance charge,
including recharging factor, Ah