10- 6
Electric pump motor –1710
Installation instructions for external temperature sensor
T-code
403-414, 669-671, 716-718
Date
2005-06-01
A fully functional temperature sensor mounted inside the motor should
have a resistance value of approx. 550 ohm at a temperature of 20
degrees.
The temperature sensor mounted on the outside has a resistance value
of approx. 670 ohm at a temperature of 20 degrees.
• The temperature sensor can be mounted to the right or left of the ter-
minal block, depending on which side is easiest to access.
• Scrape the surface clean where the new temperature sensor is to be
mounted.
• Place the temperature sensor as shown in the picture.
• Apply metallic lacquer over the sensor. Ensure that the entire sensor
is covered by the metallic lacquer.