BT REFLEX RR B Service Manual page 216

Table of Contents

Advertisement

Term.
Cable
401
117
402
118
403
119
404
120
405
121
406
122
407
125
408
126
409
127
410
128
411
65
Term.
Cable
501
50
502
51
503
82
504
83
505
84
506
85
507
27
508
28
509
62
510
86
511
129
24- 4
Electronic card – 5710
Terminal connections and voltages on A5
T-code
403-414, 669-671, 716-718
Date
2005-06-01
24.2.4 40X
Description
CAN – Serial (+)
CAN – Serial (-)
CAN H
CAN L
RS485 - Serial (+)
RS485 - Serial (-)
RS485 - TX (+), transmits data
RS485 - TX (-), transmits data
RS485 - RX (+), receives data
RS485 - RX (-), receives data
Pressure transducer, load weighing
24.2.5 50X
Description
Potentiometer acceleration, set point
Potentiometer braking, set point
Potentiometer acceleration, set point
Potentiometer extension/retraction of mast,
set point
Potentiometer tilting of forks, set point
Potentiometer extra (1) hydraulic function, set
point
Potentiometer feed
Minus to 501-506, 510
Steering tachometer (+)
Potentiometer extra (2) hydraulic function, set
point
Steering tachometer (-)
Service Manual
https://www.forkliftpdfmanuals.com/
Valid from serial number
713962-
Order number
218920-040
REFLEX RR B/E, RR B/E CC
Active
LED
(V)
+15
0
0-5
0-5
0,5-4,5
Active
LED
(V)
+3,7–1,7
+1,7–4,1
+0,66–3,7–6,6
+0,66–3,7–6,6
+0,66–3,7–6,6
+0,66–3,7–6,6
+7,35
0
Max. ±3
+0,66–3,7–6,6
0
© BT Europe AB

Hide quick links: