BT REFLEX RR B Service Manual page 243

Table of Contents

Advertisement

© BT Europe AB
Electronic card – 5710
Warning Codes without registration
Valid from serial number
713962-
Order number
218920-040
Code
16
Description
Voltage from accelerator pedal's potentiometer R1 is
outside the calibrated value at start up. (+/-0.2V).
Error mode
Start up error
Error cause
1. Activated pedal at start up
2. Faulty potentiometer/bracket/wiring
3. Calibration error.
4. Defective electronic card A5
Comments
Manoeuvre to neutral position
Accelerator, R1
1. Check that the accelerator has not stuck in the actuated posi-
tion.
2. Check that R1 is located in its bracket.
Check that there is no play or oxidisation on the connector
pins on terminal X19. The voltage on input 501 should be
3.7 +/- 0.2 VDC when R1 is correctly mechanically adjusted.
3. For calibration of the speed control, see the section "Parame-
ter setting" in this manual.
(Deactuated position).
4. If the voltage on input 501 is correct and calibration does not
rectify the problem, then replace the A5 electronic card.
Service Manual
https://www.forkliftpdfmanuals.com/
REFLEX RR B/E, RR B/E CC
T-code
403-414, 669-671, 716-718
Date
2005-06-01
24- 31

Hide quick links:

Advertisement

Table of Contents
loading