BT REFLEX RR B Service Manual page 269

Table of Contents

Advertisement

© BT Europe AB
Electronic card – 5710
Warning codes with registration
Valid from serial number
713962-
Order number
218920-040
Code
Description
Error mode
Error cause
Comments
Hydraulic valve Y13 operates the extension of the fork carriage.
1. Disconnect the cable 91 from output 703.
- Check that the connector pins make contact, no play and no oxi-
disation.
- Check that the cable 91 is intact between terminal 703 and the
terminals in X17 via X14.
- Measure the coil on Y13 between the blue and black cables in
X17 with an ohmmeter. Resistance approx. 90 ohm.
- Check that cable 40 is intact from X17 via X14 to the battery neg-
ative.
2. If the fault remains, replace A5.
Service Manual
https://www.forkliftpdfmanuals.com/
60
Output 703 short circuit/breakage
General error
1. Faulty wiring/valve Y13
2. Defective electronic card A5
REFLEX RR B/E, RR B/E CC
T-code
403-414, 669-671, 716-718
Date
2005-06-01
24- 57