41- 14
Positioning equipment – 9390
Parameters
T-code
403-414, 669-671, 716-718
Date
2005-06-01
41.11.3 Parameter 3
Programming the crawling speed for braking distances:
• State parameter 3 and press the LOAD button. The display shows
the previous programmed value for crawling speed lower. Enter the
new value using the numerical keys. The permitted max/min. values
are shown in table "Programming parameters".
• Press the LOAD button to change the crawling speed lift. The dis-
play shows the value for crawling speed. Enter the new value using
the numerical keys.
• Press the PROG button to save the new values. The display shows
P_.
41.11.4 Parameter 4
Programming the crawling distance when lifting and lowering.
• State parameter 4 and press the LOAD button. The display shows
the previous programmed value for crawling speed lower. Enter the
new value using the numerical keys. The permitted max/min. values
are shown in table "Programming parameters".
• Press the LOAD button to change the crawling speed lift. The dis-
play shows the value for crawling distance. Enter the new value us-
ing the numerical keys.
• Press the PROG button to save the new values. The display shows
P_.
41.11.5 Parameter 5
Programming the tolerance for the stop levels.
• State parameter 5 and press the LOAD button. The display shows
the previous programmed value for tolerance. Enter the new value
using the numerical keys. The permitted max/min. values are shown
in table "Programming parameters".
• Press the PROG button to save. The display shows P_.