© BT Europe AB
Electronic card – 5710
Warning Codes without registration
Valid from serial number
713962-
Order number
218920-040
Code
Description
Error mode
Error cause
Comments
Battery measurement
1. Check the voltage supply (+48 VDC) to the battery indicator,
cable 70 feeds positive to terminal 601 and cable 71 feeds ter-
minal 602 with negative.
2. Check that cable 72 and its connector are intact and make
good contact from the shunt to terminal 603. Also check that
cable 71 makes good contact with the shunt.
3. If there is no error as set out in points 1 and 2, try a new A5
card.
4. Contact the battery manufacturer for assistance in determin-
ing whether the battery is OK.
Service Manual
https://www.forkliftpdfmanuals.com/
27
Incorrect battery measurement
Battery display flashes
1. No voltage to the battery indicator
2. Poor contact on battery measurement cables
3. Defective electronic card A5
4. Defective battery
REFLEX RR B/E, RR B/E CC
T-code
403-414, 669-671, 716-718
Date
2005-06-01
24- 39