24- 90
Electronic card – 5710
Error Codes
T-code
403-414, 669-671, 716-718
Date
2005-06-01
Code
206 - 207
Description
Overheated drive regulator
Error mode
Drive regulator error
Error cause
1. Defective cooling fan
2. Defective motor, M1
3. Defective drive regulator, A1
Comments
Restart possible
1. Check the fan M12, by the frequency converters.
2. Check the drive motor and its cables.
3. If everything else is okay, replace A1.
Code
208
Description
Too high current on drive regulator
Error mode
Drive regulator error
Error cause
1. Motor cables incorrectly connected
2. Defective driving regulator, A1
Comments
Drive motor circuit
1. Check that the motor cables are intact and connected correct-
ly.
2. Replace the drive regulator, A1.