© BT Europe AB
Electronic card – 5710
Error Codes
Valid from serial number
713962-
Order number
218920-040
Code
Description
Error mode
Error cause
Comments
1. A temporary disturbance can have affected the card.
Try to restart the truck.
2. If the fault remains, despite repeated attempts to start, replace
the A5 card.
Code
Description
Error mode
Error cause
Comments
1. The relay can have opened if the truck has driven on very une-
ven ground or driven on something that has heavily affected
the truck.
Try to restart the truck.
2. If the fault remains, despite repeated attempts to start, replace
the A5 card.
Service Manual
https://www.forkliftpdfmanuals.com/
136
Error testing safety relay (main circuit) at start-up
Critical error
1. Temporary fault during test
2. Defective electronic card A5
137
Safety relay (main circuit) has opened
Critical error
1. Electronic card A5 displaced/jarred
2. Defective electronic card A5
Restart can reset
REFLEX RR B/E, RR B/E CC
T-code
403-414, 669-671, 716-718
Date