© BT Europe AB
Electronic card – 5710
Warning codes with registration
Valid from serial number
713962-
Order number
218920-040
Code
Description
Error mode
Error cause
Comments
Hydraulic valve Y17 engages a extra hydraulic function, e.g. side shift
or fork spread.
1. If a valve is not connected, parameter 15 must be set to 0.
Check parameter 15 as follows. See the section "Parameter
setting" in this manual.
2. Disconnect cable 95 from output 707.
- Check that the connector pins make contact, no play and no oxi-
disation.
- Check that the cable 95 is intact between terminal 707 and the
terminals in X50 via X15, X17 and X29.
- Measure the coil on Y17 between the green and black cables in
X50 with an ohmmeter. Resistance approx. 150 ohm.
- Check that cable 40 is intact from X50, via X29, X17 and X14 to
the battery negative.
3. If the fault remains, replace A5.
Service Manual
https://www.forkliftpdfmanuals.com/
56
Output 707 short circuit/breakage
General error
1. Parameter 15 >0, no valve connected
2. Faulty wiring/valve Y17
3. Defective electronic card A5
REFLEX RR B/E, RR B/E CC
T-code
403-414, 669-671, 716-718
Date
2005-06-01
24- 53