BT REFLEX RR B Service Manual page 231

Table of Contents

Advertisement

© BT Europe AB
Electronic card – 5710
Parameter setting of all parameters
Valid from serial number
713962-
Order number
218920-040
24.5.15 Parameter 22
Use this parameter to activate the brake coil function and monitoring,
and thus achieve higher maximum travel speed.
If the machine type is changed, next time the key is switched on new
parameters will be loaded in the frequency converters. In order for the
new parameters to take effect, the truck must be switched off and on
once again with the key.
24.5.16 Parameter 23
When this parameter is set to 1, this informs the truck controller that the
fork unit is equipped with a switching valve operating two different func-
tions. The oil flow is controlled by a valve in the large valve plate.
24.5.17 Parameter 24
When this parameter is set to 1, it is possible to stop the truck using the
drive motor but impossible to continue driving unless the safety pedal is
depressed.
24.5.18 Parameter 25
Use this parameter to determine the service interval of the truck. The
buzzer sounds and code C029 is displayed when the service counter
reaches zero. The counter shows the time that has passed since the
last service intervention.
If an earlier service intervention is required, simply activate this param-
eter without adjusting the time.
24.5.19 Parameter 26
When this parameter is set to 1, the cab tilt function (E 1-8) and moni-
toring are activated.
24.5.20 Parameter 27
When this parameter is set to 1, priority of the lifting function is can-
celled, i.e. the hydraulic function currently in use will continue to oper-
ate even if lifting is activated.
Service Manual
https://www.forkliftpdfmanuals.com/
REFLEX RR B/E, RR B/E CC
T-code
403-414, 669-671, 716-718
Date
2005-06-01
24- 19

Hide quick links: