BT REFLEX RR B Service Manual page 418

Table of Contents

Advertisement

38- 16
Battery charger – 8340
Service and maintenance
T-code
403-414, 669-671, 716-718
Date
2005-06-01
38.4.6 Trouble shooting
If an error occurs during charging this normally results in one or more
error messages. Some errors are such that the computer does not dis-
play the error, e.g. a fault on the electronic card. Here follows a compi-
lation of errors and appropriate actions
Error message, analysis and action
E.22
= low counter-voltage.
The connected battery has too low counter-voltage.
• Check the battery and its connections.
E.30 - E.36
= high temperature on component parts.
• Check the fan
• Check that the ventilation openings are not covered.
• Check that the mains voltage adaptation is correct.
• Check that the ambient temperature is not too high.
E.25
= low current.
• Check that there is no play on the battery plug or battery poles.
• Check that the battery is not sulphated.
• Check the contactors.
• Check the temperature fuses.
• Check for a possible error on the mother board.
E.52
= phase fault.
• Check the fuses on the mains.
• Check that all phases are present.
• Check for play on the mains terminal.
• Check for any diode failure.
• Check that the right mains voltage code has been programmed.
E.60, E.70
= incorrect information in the mother board's EE-prom.
• Reprogram and calibrate if necessary.
• Copy over the data.
• Switch off the charger and then restart.
• Check that the error message has disappeared.
E.72
= error in the mother board's EE-prom
• Check the EE-prom.
• Check the computer board.
Service Manual