BT REFLEX RR B Service Manual page 455

Table of Contents

Advertisement

© BT Europe AB
Positioning equipment – 9390
Parameters
Valid from serial number
713962-
Order number
218920-040
41.11 Parameters
There are a number of parameters that can be modified in the pre-set
height program.
• Press the button PROG for three seconds to start programming rou-
tines. The LED comes on and the display shows P_ _ _ .
• Enter code 852 using the numerical keys and the display will now
show P_.
• State the required parameter 1 - 9 and then press the LOAD button.
The display shows the factory settings. These can be changed to
any of the max/min. values shown in the table "Programming param-
eters".
NOTE!
If a value outside the max/min. range is programmed in, this will be re-
placed by the max/min. factory setting.
• Press the STOP button to terminate programming.
41.11.1 Parameter 1
Select the unit of measurement you wish to use (metres or inches).
• Press the PROG button to save the unit you selected. The display
shows P_.
41.11.2 Parameter 2
If the distance between lifting heights is equal on all levels, you can
make a common program:
• State parameter 2 and press the LOAD button. The display shows P
00 and you now enter the number of levels. Press the LOAD button
and the display shows P000.
• Specify the collect height for the first level in increments of 10 mm.
Press the LOAD button and the display shows P000.
• The next value you need to enter is the distance between collect/de-
posit level in increments of 10 mm. Press the LOAD button and the
display shows P000.
• The next value you need to enter is the distance between each de-
posit level in increments of 10 mm. Press the PROG button to save
programmed values. The display shows P_.
Service Manual
https://www.forkliftpdfmanuals.com/
REFLEX RR B,E RR B,E CC
T-code
403-414, 669-671, 716-718
Date
2005-06-01
41- 13