BT REFLEX RR B Service Manual page 304

Table of Contents

Advertisement

24- 92
Electronic card – 5710
Error Codes
T-code
403-414, 669-671, 716-718
Date
2005-06-01
Code
211 - 212
Description
Too low voltage on drive regulator
Error mode
Drive regulator error
Error cause
1. Charger plug removed with ignition key S17
switched on
2. External current load incorrectly connected
3. Faulty wiring/fuse F62
4. Defective drive regulator, A1
5. Defective electronic card, A5
Comments
Main contactor, K10
1. If you forget to switch off the truck and pull out the charging
plug an error code is given.
2. Check that no extra equipment overloads the electrical sys-
tem.
3. Check that there is 48 VDC on input 808,
cable 23 when K10 is activated. If not, check the fuse F62 (10
A), contactor points on K10 and the cables 1, 8 and 23.
4. If this does not help, replace A1.
5. Replace A5.
Service Manual
REFLEX RR B/E, RR B/E CC
https://www.forkliftpdfmanuals.com/
Valid from serial number
713962-
Order number
218920-040
© BT Europe AB