24- 44
Electronic card – 5710
Warning Codes without registration
T-code
403-414, 669-671, 716-718
Date
2005-06-01
Code
45
Description
Warning temperature for pump motor
Error mode
Maximum current reduced
Error cause
1. Overheated pump motor
2. Faulty temperature sensor/wiring
3. Defekta lyftregulatorer, A2
Comments
Temperature sensor B2 in the pump motor M3
1. Check that the ventilation is okay, especially the fan M10 in the
motor compartment.
2. Check B2.
- Remove connection X12. Measure B2 in X12 with the ohmmeter,
approx. 570 ohm at 20
- Check that cable 16 is intact between X12 and terminal 4 on A1.
- Check that cable 19 is intact between X12 and terminal 7 on A1.
- Also check the connector pins on the terminals for play and oxidi-
sation.
3. If B2 and its cables are okay, replace A2.