Parameter
Operating voltage
Maximum voltage
Minimum operating voltage
Frequency
Contactor voltage
Ambient operating temperature
Current limit, down-regulation
with overheating of the heatsink
Current limit, down-regulation at
excessively low cooling block
temperatures
Current limiting
Speed
© BT Europe AB
Transistor panel – 5460
Frequency converter
Valid from serial number
713962-
Order number
218920-040
23.1.2 Technical Data
Setting
ACS 4808
48
65
30
13
48
-35 - +55
85
-20
250
100
23.1.3 Installation of new frequency
converter on truck
Frequency converters from BT Parts can be delivered in different con-
figurations:
1. Ready programmed with complete number
= part number for frequency converter including program.
2. Non-programmed at part number
= only part number for frequency converter.
When installing a new card, certain parameters must be reprogrammed
so that the truck can be safely operated.
23.1.4 Programming
For downloading new programs to the electronics card, the Truck Com
service program is used.
See the Truck Com user manual for a description of the procedure.
Service Manual
https://www.forkliftpdfmanuals.com/
Setting
Unit
ACS 4811
48
Volt
65
Volt
30
Volt
8/13
kHz
48
Volt
-35 - +55
°C
85
°C
-20
°C
350
Amp
100
%
REFLEX RR B/E, RR B/E CC
T-code
403-414, 669-671, 716-718
Date
2005-06-01
Description
Over-voltage point
Under-voltage point
0 A at 125°C
50% current limiting at
start
2 minutes
Modulation
23- 3