BT REFLEX RR B Service Manual page 464

Table of Contents

Advertisement

42- 22
TV equipment – 9390
Camera mounted on fork
T-code
403-414, 669-671, 716-718
Date
2005-06-01
42.2.3 Voltage converter A10
A10 converts incoming voltage 48 V into 12 V, which is fed to the TV
monitor and camera.
Parameter
Input voltage
Output voltage
Max. operating volt-
age
Min. operating voltage
Max. continuous cur-
rent
Max. intermittent cur-
rent
Fuse on input
The converter is protected on the input side against polarity variation,
short circuits and thermal overload.
The chassis is not live, and the in/outputs are galvanically separated.
For further information, see Wiring diagram C code 5000.
Service Manual
REFLEX RR B,E RR B,E CC
https://www.forkliftpdfmanuals.com/
Valid from serial number
713962-
Order number
218920-040
Setting
Unit
48
Volt
13.2
Volt
64
Volt
40
Volt
6
Amp
8
Amp
6.3
Amp
Description
© BT Europe AB