© BT Europe AB
Battery charger – 8340
Functional description
Valid from serial number
713962-
Order number
218920-040
Once all the changes have been made a copy-over can be made with
code 22.
• Press * 22 * 2451 *.
2451 is a safety code to avoid data being changed unintentionally. If
charging is in progress the contactors release during the actual copying
process.
Reading parameters
The program and component circuit boards have the same design irre-
spective of the charger's rated voltage or current. Values are set by
storing parameters concerning the battery and charger in the parame-
ter memory (EE-prom). These values are written during final testing of
the device.
NOTE:
There are other parameters that are set at the factory and are not de-
scribed here. Default values are values written during the functions
basic programming. The significance of the register is shown in the
following table:
• Press * register *.
Battery specific parameters
Register Function (resolution, unit)
200
Battery capacity, Ah
210
Recharging factor, %
230
No. of cells
220
Current that loads the battery during charg-
ing, 100 mA
224
Cold storage operations, 0 = no, 1 = yes
1)
Start voltage for maintenance charging
215
pulse, 10 mV/cell.
1)
Lower statistic level ((25 + (y×5))%)
204
y=at value between 1 and 15, e.g. ((25 +
(2×5))%)=35%
1)
Statistic range ((z×2)%)
205
z=optional value for the required range,
e.g. ((10×2)%)=20%
1)
Only applies to program version 1.19 or later.
Service Manual
https://www.forkliftpdfmanuals.com/
REFLEX RR B/E, RR B/E CC
T-code
403-414, 669-671, 716-718
Date
2005-06-01
Default
value
0
15
0
0
0
217
1
10
38- 9