BT REFLEX RR B Service Manual page 263

Table of Contents

Advertisement

© BT Europe AB
Electronic card – 5710
Warning codes with registration
Valid from serial number
713962-
Order number
218920-040
Code
Description
Error mode
Error cause
Comments
Hydraulic valve Y14 engages fork tilt down
1. Disconnect the cable 92 from output 704.
- Check that the connector pins make contact, no play and no oxi-
disation.
- Check that the cable 92 is intact between terminal 704 and the
terminals in X17 via X14.
- Measure the coil on Y14 between the orange and black cables in
X17 with an ohmmeter. Resistance approx. 90 ohm.
- Check that cable 40 is intact from X17, via X14 to the battery neg-
ative.
2. If the fault remains, replace A5.
Service Manual
https://www.forkliftpdfmanuals.com/
54
Output 704 short circuit/breakage
General error
1. Faulty wiring/valve Y14
2. Defective electronic card A5
REFLEX RR B/E, RR B/E CC
T-code
403-414, 669-671, 716-718
Date
2005-06-01
24- 51

Hide quick links:

Advertisement