BT REFLEX RR B Service Manual page 267

Table of Contents

Advertisement

© BT Europe AB
Electronic card – 5710
Warning codes with registration
Valid from serial number
713962-
Order number
218920-040
Code
Description
Error mode
Error cause
Comments
Hydraulic valve Y19 engages a extra hydraulic function, e.g. side shift
or fork spread.
1. If a valve is not connected, parameter 16 must be set to 0.
Check parameter 16 as follows. See the section "Parameter
setting" in this manual.
2. Disconnect cable 96 from output 708.
- Check that the connector pins make contact, no play and no oxi-
disation.
- Check that the cable 97 is intact between terminal 709 and the
terminals in X16 via X15.
- Measure the coil on Y18 between the cable in X16 and the cable
in X17 with an ohmmeter. Resistance approx. 150 ohm. (Not
standard)
- Check that cable 40 is intact from X17, via X14 to the battery neg-
ative.
3. If the fault remains, replace A5.
Service Manual
https://www.forkliftpdfmanuals.com/
58
Output 709 short circuit/breakage
General error
1. Parameter 16 >0, no valve connected
2. Faulty wiring/valve Y19
3. Defective electronic card A5
Non standard, accessory
REFLEX RR B/E, RR B/E CC
T-code
403-414, 669-671, 716-718
Date
2005-06-01
24- 55

Hide quick links: