BT REFLEX RR B Service Manual page 272

Table of Contents

Advertisement

24- 60
Electronic card – 5710
Warning codes with registration
T-code
403-414, 669-671, 716-718
Date
2005-06-01
Code
64
Description
Pressure sensor short-circuited/interrupted
Error type
If the pressure sensor is defective, the maximum
travel speed will be limited to 9 km/h
Error causes
1. Defective cabling/B3 sensor B3
2. Defective A5 electronic card
Note
1. Measure the voltage on input 411 on the A5 electronic card A5.
It must be between >0.3 and <6 volts.
2. Measure the voltage to the sensor on cable 29/30. It must be 15
volts.
3. Disconnect cable 65 from output 411.
- Check whether the connector terminals have contact, are loose
or oxidised.
- Check whether cable 65 is intact between the 411 connector and
the X47 connector.
- Check whether cable 65 is intact between the X47 connector and
the X54 connector.
- Check whether cable 29/30 is intact between B3 and X54 and the
connector in X14.
- Check whether the cable 29/30 is intact from X14 to the A5 elec-
tronic card.
4. Replace A5 if the error remains.
Service Manual
REFLEX RR B/E, RR B/E CC
https://www.forkliftpdfmanuals.com/
Valid from serial number
713962-
Order number
218920-040
© BT Europe AB