Electronic card – 5710
Error Codes
Valid from serial number
713962-
Order number
218920-040
24.11.1 Error codes with registration
Code
Description
Error mode
Error cause
Comments
Parking brake Y1
1. Check that the switch S131 is open.
2. Disconnect the cable 64 from output 802.
- Check that the connector pins make contact, no play and no oxi-
disation.
- Check that the cable 64 is intact between terminal 802 and the
terminals in X37.
- Measure the coil on Y1 between the terminals in X37 with an
ohmmeter. Resistance approx. 33 ohm.
- Check that cable 40 is intact from X37 to the battery negative.
3. If the fault remains, replace A5.
Service Manual
https://www.forkliftpdfmanuals.com/
104
Output 802 short circuit/breakage
Critical error
1. Emergency switch for Y1 activated
2. Faulty wiring/valve Y1
3. Defective electronic card A5
REFLEX RR B/E, RR B/E CC
T-code
403-414, 669-671, 716-718
Date
2005-06-01
24- 67