BT REFLEX RR B Service Manual page 229

Table of Contents

Advertisement

© BT Europe AB
Electronic card – 5710
Parameter setting of all parameters
Valid from serial number
713962-
Order number
218920-040
24.5.12 Parameter 19
Lift
Rough setting
height:
B/E 1-6 mast with inte-
grated side shift
4400
1,42
4600
1,50
4800
1,56
5400
1,75
5700
1,85
6300
2,07
6750
2,22
7000
2,42
7500
2,56
8000
2,74
8500
2,93
9000
3,09
9500
3,19
10000
10500
10800
24.5.13 Parameter 20
Use this parameter to set whether operating hours, A-d, S or weight
measurement shall be displayed when the truck is operated.
24.5.14 Parameter 21
Use this parameter to set the type of battery installed on the truck. This
parameter can also be used to compensate for different driving styles.
For additional information about battery installation and setting the bat-
tery parameters, please see section 5110.
When setting the battery guard check-point, perform measurement as
follows:
• Specific gravity with fully charged battery. Use to inspect the battery
quality.
When the battery indicator shows 80% discharge, minimum specific
gravity is 1.14.)
Service Manual
https://www.forkliftpdfmanuals.com/
REFLEX RR B/E, RR B/E CC
T-code
403-414, 669-671, 716-718
Date
2005-06-01
Rough setting
B/E7-8
1,65
1,84
2,14
2,38
2,48
2,83
3,01
3,14
3,27
3,43
3,58
3,70
24- 17