BT REFLEX RR B Service Manual page 226

Table of Contents

Advertisement

Table 7: List of parameters
No. Parameter type
29
Maximum lift height
30
I/O box
37
Calibration weight for
weighing
38
Calibration of accel-
eration/brake pedal/
reach carriage and
weight.
39
Driver access
40
Time, year
41
Time, day
42
Time, month
24- 14
Electronic card – 5710
Parameter setting of all parameters
T-code
403-414, 669-671, 716-718
Date
2005-06-01
Unit
Min./max. Std.
m
0-13,5
1
0-2
kg
100–5000
1
0-4
1–4
Year
0–99
Day
1–31
Month
1–12
Service Manual
REFLEX RR B/E, RR B/E CC
https://www.forkliftpdfmanuals.com/
Valid from serial number
713962-
Order number
218920-040
Comments
value
13,5
0 = not connected
> 0 = connected
In steps of 0.05
0
0 = No I/O module connected
1 = Output 1 hydraulics
Output 2 driving
2 = Output 1 driving in drive wheel
direction
Output 2 driving in fork direction
1000
In steps of 10
0
1 =Calibration of speed- brake
potentiometer and reach carriage
distance
2 = Not used
3 =Not used
4 = Weight calibration
3
1 = Key, open
2 = Key, locked
3 = Keypad, open
4 = Keypad, locked
In steps of 1
In steps of 1
In steps of 1
© BT Europe AB

Hide quick links:

Advertisement

Table of Contents
loading