BT REFLEX RR B Service Manual page 280

Table of Contents

Advertisement

24- 68
Electronic card – 5710
Error Codes
T-code
403-414, 669-671, 716-718
Date
2005-06-01
Code
106
Description
Output 804 short circuit/breakage
Error mode
Critical error
Error cause
1. Faulty wiring/contactor K10
2. Defective electronic card A5
Comments
Main contactor, K10, coil
1. Disconnect the cable 31 from output 804.
- Check that the connector pins make contact, no play and no oxi-
disation.
- Check that cable 31 is intact up until contactor K10:A2.
- Measure the coil on Y10 between A1 and A2.
Resistance approx. 150 ohm.
- Check that cable 40 is intact between contactor K10: A1 and the
battery negative and terminals in X38.
2. If the correct voltage is on input 501 and the fault remains, re-
place the A5 electronic card.
Service Manual
REFLEX RR B/E, RR B/E CC
https://www.forkliftpdfmanuals.com/
Valid from serial number
713962-
Order number
218920-040
© BT Europe AB