BT REFLEX RR B Service Manual page 408

Table of Contents

Advertisement

38- 6
Battery charger – 8340
Functional description
T-code
403-414, 669-671, 716-718
Date
2005-06-01
Error indication and error messages
When one or more LEDs flash an error has occurred, after which the
display automatically, or after pressing the # key, shows the error
codes. Older program versions demand the # key to be pressed once
per error code.
Code
Error messages
E01
Error code has been entered
E02
Entered value is too large
E03
Error in EE-prom
E10
Mains error
E11
Direct voltage error
E12
Interrupted secondary fuse
E13
Safety shutdown
E14
High temperature
E17
Error in EE-prom
E20
Great need of maintenance charging
E21
High counter-voltage, across 2.4 V/cell
E22
Low counter-voltage, across 1.8 V/cell
E23
Overcurrent, more than double the rated current
E25
Too low current, less than 1% of the rated current
E26
Tripped secondary fuse
E30
High temperature, on transformer or choke
E31
High temperature on the diode heatsink
E32
High ambient temperature
E36
Fan fault
E40
Too low current, less than 1% of the rated current
E43
Charged capacity> programmed capacity × recharging
factor
E44
Long charging time with voltage over 2.37 V/cell
E52
Phase missing on 3 phase charger
E60
Checksum error in EE-prom
E61
Keyboard error. Key pressed > 20 seconds
E62
Communication error with printer
Service Manual
REFLEX RR B/E, RR B/E CC
https://www.forkliftpdfmanuals.com/
Valid from serial number
713962-
Order number
218920-040
© BT Europe AB

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents